Official GSK Agents in South Africa
Tel: +27 11 626 2720, [email protected]
GSK980TDi Turning CNC System User Manual
362
Ⅱ
Operation
17) Switch to tool offset, move the cursor to No.004 offset and input X135 Z0;
18) Move the tool to a safe position after the tool-setting is finished;
19) Start the machining in Auto mode;
20) If there is any error between the designed and the actual dimensions, the tool offset may be
altered till the part dimensions are within the tolerance.
Note: Press
key to make the auto running to pause if dwell is needed during the machining. Also if
emergency occurs, the user presses the
key, Emergency stop button to cut off the power to
terminate the program running.