Official GSK Agents in South Africa
Tel: +27 11 626 2720, [email protected]
GSK980TDi Turning CNC System User Manual
472
Ⅲ
Connection
[
Data unit
]
%
[
Data range
]
0
~
100
Formula=|current speed
-
previous period speed|×200/(current speed
+
previous period speed)
1 0 7
THD_TAIL_SPD
[
Data meaning
]
Short axis speed in threading run-out (run-out by threading feedrate if set to 0)
[
Data unit
]
Set unit
Data unit
Metric machine
mm/min
Inch machine
0.1inch/min
[
Data range
]
0
~
8000
3.2.7 Spindle Control
0 0 1
SPIN
Bit4 1: Analog voltage control of spindle speed
0: Switching volume control of spindle speed
K
1 0
RSJG
RSJG 1: when the reset is pressed, CNC does not close M03,M04,M08,M32 output signal
;
0: when the reset is pressed, CNC closes M03, M04, M08, M32 output signal
0 2 1
PSANGNT
[
Data meaning
]
voltage offset offset value when the analog voltage outputs 10V.
[
Data unit
]
mV
[
Data range
]
-2000
~
2000
0 3 6
SPDLC
[
Data meaning
]
voltage offset offset value when the analog voltage outputs 10V.
[
Data unit
]
mV
[
Data range
]
-1000
~
1000
0 3 7
GRMAX1
0 3 8
GRMAX2
0 3 9
GRMAX3
0 4 0
GRMAX4
[
Data meaning
]
GRMAX1, GRMAX2, GRMAX3, GRMAX4: Max. speeds of spindle gear 1, 2,
3, 4
respectively when analog voltage output is 10V (function defined by
GSK980TDi PLC: if the spindle automatic gearing is active, they are the
speeds of M41, M42, M43, M44; if the automatic gearing is inactive or CNC is
powered on, the gears are memorized by parameter setting or the gear 1 is
defaulted.)
[
Data unit
]
r/min