Official GSK Agents in South Africa
Tel: +27 11 626 2720, [email protected]
Chapter 3 Parameters
449
Ⅲ
Connection
0 9 9
PECINTn
[
Data type
]
Word
axis
[
Data meaning
]
Pitch error compensation intervals
[
Data unit
]
Setting unit
IS-B
IS-C
Metric machine
0.001 mm
0.0001 mm
Inch machine
0.0001 inch
0.00001 inch
[
Data range
]
IS-B IS-C
Metric machine 1000
~
999999
10000
~
9999999
Inch machine
400
~
999999 4000
~
9999999
1 0 0
LTMAX_2
1 0 1
LTMIN_2
[
Data type
]
Word
axis
[
Data meaning
]
Stored stroke limit 2 of each axis, LTMAX_2 positive maximum stroke position,
LTMIN_2 negative maximum stroke position.
[
Data unit
]
Setting unit
IS-B
IS-C
Metric machine
0.001 mm
0.0001 mm
Inch machine
0.0001 inch
0.00001 inch
[
Data range
]
-99999999
~
99999999
1 0 2
LTMAX_3
1 0 3
LTMIN_3
[
Data type
]
Word
axis
[
Data meaning
]
Stored stroke limit 3 of each axis, LTMAX_3 positive maximum stroke position,
LTMIN_3 negative maximum stroke position.
[
Data unit
]
Setting unit
IS-B
IS-C
Metric machine
0.001 mm
0.0001 mm
Inch machine
0.0001 inch
0.00001 inch
[
Data range
]
-99999999
~
99999999
1
0
6
THD_SPD_VAR
[
Data meaning
]
Spindle fluctuation alarm limit in threading (not detect spindle fluctuation alarm
if set to 0)
[
Data unit
]
%
[
Data range
]
0
~
100
Formula=|current speed
-
previous period speed|×200/(current speed
+
previous period speed)
1 0 7
THD_TAIL_SPD
[
Data meaning
]
Short axis speed in threading run-out (run-out by threading feedrate if set to 0)