GSK980TDi Turning CNC System User Manual
42
Ⅰ
Programming
Press repetitively
into the tool life management display window
.
1
)
“Tool compensation->tool life” window
The current window displays the life management data of current used tool life management and
defined tool groups. The window is shown below:
Current tool state: display the current used tool life management data;
Tool number: current used tool and tool compensation number;
Group: the group where the tool is;
Life:
tool life data, the specified value can be time or number of times according to the different
count N value; press
to record the time or clear the times.
Used: used tool life data.
Life unit:
count unit of tool life, N1 is the used time (unit: minute), N0 is the used times (unit:
times) . Press
,
to change the count unit of the tool.
State
:
display the tool state
(
0
-
not be used
,
1
-
being used
,
2
-
used
,
3
-
skip
)
.
Press
to change the tool state to skip when the tool is not used in the current window.
Defined group:
It only display defined group number and the undefined group number is not
displayed. The displayed group back lighted means that all tool life in this group is
over.
2) Creating and displaying tool group number
A. In tool group state display window, press
, group number,
and the system
display the tool group life data, and when the group does not exist, it is defined to the new
group number( the parameter switch is ON in MDI mode).
Note: After the new group is defined, GSK980TDi will automatically define the first tool, for
example, the new defined group number is 01, the display is as follows: