Official GSK Agents in South Africa
Tel: +27 11 626 2720, [email protected]
GSK980TDi Turning CNC System User Manual
36
Ⅰ
Programming
spindle has not received the spindle selection signal, it rotates with the previous speed, which makes
the spindle rotates with different speed in different time. Each spindle has its own stop signal and
enabling signal.
When
№
001
#
4 is set to 1, setting MSEN
(
№
196
#
4
)
to 1 can start the multiple spindle control
function.
The spindle control has several methods which are set by MSI
(
№
196
#
7
)
as follows:
z
Multiple spindle control method A
When SWS1 signal selects the 1
st
spindle, SIND signal is used to determine that the spindle
analog voltage is controlled by PLC or CNC, R011 to R121 signals are used to set the spindle analog
voltage. These signals do not influence the 2
nd
spindle.
Multiple spindle control method A is shown below.
z
Multiple spindle control method B
Each spindle has separate SIND signal.
When the spindle selection signal, the 1
st
spindle or the 2
nd
spindle SIND signal is set to 1, SIND
signals separately determine each spindle to be controlled by PLC or CNC.
Multiple spindle control method B is shown below.
z
Multiple spindle control function being invalid
When the multiple spindle control is invalid, the control method is shown below.