![GSK 980TDi User Manual Download Page 416](http://html1.mh-extra.com/html/gsk/980tdi/980tdi_user-manual_2275219416.webp)
Official GSK Agents in South Africa
Tel: +27 11 626 2720, [email protected]
GSK980TDi Turning CNC System User Manual
400
Ⅲ
Connection
PC
signal
Ignore
PC
Time (T)
Sequence of
machine zero
High return
speed
Low
return
speed
Velocity (V)
Fig. 2-44
The process of machine zero return in method D:
A: Select the mechanical zero return method, positively feed manually, the corresponding axis
moves to the zero direction at the rapid traverse rate.
B: When met the one-turn signal (PC) of the servo axis at the first time, the system
decelerates to the zero return.
C: When the system decelerates to the zero return, the system is then detected the one-turn
signal again (PC).
D: The system operation stops when mets the one-turn signal (PC) of the servo axis;
simultaneously, the zero return indicator of if its corresponding axis on the operation panel
is turned on, the mechanical zero return is then ended.
2.9.4 Spindle Control
z
Relevant signal (by standard PLC program)
Type Sign
Interface
Address
Function
Remark
Input
signal
SALM
CN15.8
X5.0
Spindle abnormity alarm input
M03 CN62.4 Y0.3
Spindle
rotation(CCW)
M04 CN62.5 Y0.4
Spindle
rotation(CW)
M05 CN62.6 Y0.5
Spindle
stop
SPZD CN62.8 Y0.7
Spindle
brake
SFR CN15.6 Y5.0
Spindle
rotation(CW)
Its function is
consistent with
that of M03
Output
signal
SRV CN15.7 Y5.1
Spindle
rotation(CCW)
Its function is
consistent with
that of M04
M03 Spindle
rotation(CCW)
M04 Spindle
rotation(CW)
Command
format
M05
Spindle
stop
Note: When the spindle is serial-connected, system delivers the rotation signal to servo by