Official GSK Agents in South Africa
Tel: +27 11 626 2720, [email protected]
GSK980TDi Turning CNC System User Manual
460
Ⅲ
Connection
0: When spindle stop command is in the same block with movement command, movement
command comes first to spindle stop command;
Bit4 1: When cooling OFF command and movement command are in the same block, they are
executed at the same time;
0: When cooling OFF command and movement command are in the same block, movement
command comes first to the cooling OFF command;
Bit2 1: the lubricating outputs in power-on when the automatic lubricating is enabled;
0: the lubricating does not output in power-on when the automatic lubricating is enabled.
Bit1 1: the external feedrate override inverses;
0: the external feedrate override does not inverse.
Bit0 1: the external feedrate override switch is enabled
0: the external feedrate override switch is disabled.
K 1 7 MSEN
SCLP SALM2 SALM
SSTP
***
*** SPDIR
Bit7 1: the multiple spindle control function is enabled;
0: the multiple spindle control function is disabled.
Bit6 1: the spindle clamped command clamps the 2
nd
spindle when the multiple spindle is
enabled;
0: the spindle clamped command clamps the 1
st
spindle when the multiple spindle is enabled
Bit5 1: the system alarms when the 2
nd
spindle is LOW;
0: the system alarms when the 2
nd
spindle is HIGH.
Bit4 1: the system alarms when the spindle is LOW;
0: the system alarms when the spindle is HIGH.
Bit3 1: the analog voltage is disabled when the spindle stops;
0: the analog voltage is enabled when the spindle stops.
Bit0 1: The spindle button rotation direction on the panel is reversed;
0: The spindle button rotation direction on the panel is positive.
K 1
8 EXTM
RSTM
HOLD
*** MDOK
MD4 MD2 MD1
Bit7 1: extended M function is valid;
0: extended M function is invalid
Bit6 1: extended M function remains output when emergency stop, reset;
0: extended M function output closes when emergency stop, reset.
Bit5 1: HOLD release control is valid;
0: HOLD release control is invalid.
Bit3 1: the operation mode is specified by MD4, MD2, MD1 state when the system is turned on;
0: the operation mode is the state which is that of power-off when the system is turned on.
MD4
MD2
MD1
Operation mode in power-on
0 0 0
MDI
mode
0 0 1
Auto
mode
0
1
0
Program zero return
0 1 1
Edit
mode
1 0 0
MPG
mode
1 0 1 Manual
mode
1
1
0
Machine zero return