Official GSK Agents in South Africa
Tel: +27 11 626 2720, [email protected]
Chapter 2 Definition and Connection of Interface Signal
377
Ⅲ
Connection
Fig.2-16 CN61
inputinterface
(male socket
of 44-cord in
type D)
Note: Partial input interface is the fixed address for some functions, for example: the signal of ESP, DECX,
DECZ or SKIP, etc. If this function does not use, it will be redefined in PLC.
Pin Address
Function
Explanation
21
~
24
0V
Power supply
interface
17
~
20
25
~
28
Floating Floating
Floating
1
X0.0
SAGT
Guard door check signal
2 X0.1 Reserved
Reserved
3
X0.2
DIQP
Chuck input signal
4
X0.3
DECX(DEC1)
X deceleration signal(fixed address )
5
X0.4
DITW
Tailstock control signal
6 X0.5
ESP
External emergency stop signal
(fixed address )
7
X0.6
PRES
Pressure check signal
8 X0.7
T05
Tool signal 5 /Sensor E
(LIO_SHING Tool Post )/YA_XING locking
signal
9 X1.0 T06/
strobe
Tool signa l 6/ strobe signal
(YantaiAK31)/Sensor F(LIO_SHING Tool
Post )
10 X1.1
T07/
pregraduation
Tool signal 7 /OV3/pregraducation proximity
switch(YantaiAK31)/YA_XING releasing
11 X1.2
T08/ tool post
worktable overheat
Tool signal 8//tool post worktable overheat
check (YantaiAK31)
12
X1.3
DECZ(DEC3)
Z deceleration signal(fixed address )
13 X1.4 Reserved Reserved
14
X1.5
M41I
Shifting gear to 1st gear in-position
15
X1.6
M42I
Shifting gear to 2nd gear in-position
16 X1.7
T01
Tool signal
/
Sensor A(LIO_SHING Tool
Post )
29 X2.0
T02
Tool signal
/
Sensor B (LIO_SHING Tool
Post )
30 X2.1
T03
Tool signal
/
Sensor C (LIO_SHING Tool
Post )
31 X2.2
T04
Tool signal
/
Sensor D (LIO_SHING Tool
Post )
32
X2.3
DECY(DEC2)
Y deceleration signal(fixed address )
33 X2.4 DEC4/LUBS
4th deceleration signal(fixed
address )/lubricating oil detection
34
X2.5
DEC5
5th deceleration signal(fixed address )/
35
X2.6
TCP
Tool post clamping signal
36
X2.7
EXHP
external hydraulic control input
37 X3.0
LMIX X
overtravel
38 X3.1
LMIY Y
overtravel
39 X3.2
LMIZ Z
overtravel
40
X3.3
WQPJ/VPO2
Chuck releasing in-position signal
41
X3.4
NQPJ/SALM2
Chuck clamping in-position signal
42
X3.5
SKIP
G31 skip signal
43
X3.6
AEX
X tool measure position arrival signal (G36)
44
X3.7
AEZ
Z tool measure position arrival signal (G37)