![GSK 980TDi User Manual Download Page 467](http://html1.mh-extra.com/html/gsk/980tdi/980tdi_user-manual_2275219467.webp)
Official GSK Agents in South Africa
Tel: +27 11 626 2720, [email protected]
Chapter 3 Parameters
451
Ⅲ
Connection
1
1
9
KEY_P_NUM
[
Data meaning
]
Number of active keys at a time
[
Data unit
]
piece
[
Data range
]
2
~
5
1
2
0
REF1_COORDn
1
2
1
REF1_COORDn
1
2
2
REF2_COORDn
1
2
3
REF2_COORDn
[
Data type
]
Word
axis
[
Data meaning
]
REF1_COORDn 1st reference point machine coordinates
;
REF2_COORDn 2
nd
reference point machine coordinates
;
REF3_COORDn 3
rd
reference point machine coordinates
;
REF4_COORDn 4
th
reference point machine coordinates
[
Data unit
]
Setting unit
IS-B
IS-C
Metric input
0.001 mm
0.0001 mm
Inch input
0.0001 inch
0.00001 inch
[
Data range
]
-99999999
~
99999999
1 3 6
FPGA_JMP_XPL
[
Data type
]
Word
[
Data meaning
]
Tool offset testing input in method B, X plus direction test signal add
(0:invalid;20~27,30~37:add X2.0~X3.7)
[
Data range
]
0, 20~27, 30~37
1 3 7
FPGA_JMP_XML
[
Data type
]
Word
[
Data meaning
]
Tool offset testing input in method B, X minus direction test signal add
(0:invalid;20~27,30~37:add X2.0~X3.7)
[
Data range
]
0, 20~27, 30~37
1 3 8
FPGA_JMP_ZPL
[
Data type
]
Word
[
Data meaning
]
Tool offset testing input in method B, Z plus direction test signal add
(0:invalid;20~27,30~37:add X2.0~X3.7)
[
Data range
]
0, 20~27, 30~37
1 3 9
FPGA_JMP_ZML
[
Data type
]
Word
[
Data meaning
]
Tool offset testing input in method B, Z minus direction test signal add
(0:invalid;20~27,30~37:add X2.0~X3.7)