GSK980TDi Turning CNC System User Manual
326
Ⅱ
Operation
Note 1: The degradation operation cannot be executed when the current level is the 6
th
grade.
Note 2: The current password can be altered after degradation. When the system is in the high level, the
degradation can be executed to set to the low-level password.
11.1.3 Parameter Operation
The parameter data (state parameter, data parameter) can be backup (stored) and recovered
(read). Programs can be stored in the CNC when the backup or recovery is executed. The display is
shown below:
1) Option
explanation:
Backup current parameters (user): the user to backup the CNC data (store)
Resume backup parameters(user): the user resumes the backup data (read)
Resume parameter (servo 1u level): the user reads the original parameter data matched
with the servo drive with the precision 1um
Resume parameter (servo 0.1u level): the user reads the original parameter data matched
with the servo drive with the precision 0.1um
Note: When the level is the 2
nd
grade, the backuping current parameters (user ) and resuming backup
parameters (user) become backuping current parameters (machine manufacturer) and resuming backup
parameters (machine manufacturer), which is used to backup and resume the manufacturer’s data.
2) Operation
methods:
a)
Open the parameter switch;
b)
Press
to enter the MDI mode, move the cursor the required item;