GSK980TDi Turning CNC System User Manual
342
Ⅱ
Operation
12.3.2 Backup/Resume Operation
1) Press
,
,
,
to move the cursor to the required option;
2) Press
(
or
)
to select the required option to be backup/resumed;
3) Press
(or
) to cancel the selection when the cursor has been in the selected
option;
4) Press
or
to select or cancel all selection;
5) Press
(
or
)
to execute the current selected.
Note 1: Data which has been backup or has been done to store in the U disk can be resumed.
Note 2: When the cursor is in the “BACKUP OPTION” column, all options in the the “RESUME OPTION”
column cannot be selected; when the cursor is in the “RESUME OPTOIN”, all options in the
“BACKUP OPTION” column cannot be selected;
Note 3: Pressing
executes operations only in the column where the cursor is. When the cursor is in
“BACKUP OPTION” column, the resume operation is executed. The backup, resume cannot be
executed simultaneously.
12.3.3 Operation Path Selection
When the user uses the U disk to execute the CNC data backup, the CNC creates a backup file
“gsk980TDi_backup” in the root catalog of the U disk. The backup file includes two backup data “U:\
gsk980TDi_backup\user” and “U:\ gsk980TDi_backup\serial number” (it is created by the system’s
serial number). When the user uses one U disk to execute data backup of many CNC systems, the
data in “U:\ gsk980TDi_backup\user” is replaced by the new but data in “U:\ gsk980TDi_backup\serial
number” remains unchanged.
For the above reason, the user should execute the operation path selection during resuming
data: