Official GSK Agents in South Africa
Tel: +27 11 626 2720, [email protected]
Chapter 5 Diagnosis Message
515
Ⅲ
Connection
Address Alarm
No.
Content
A0003.4
1028
Has not found the target tool
A0003.5
1029
Has not received tool pot stop and locking start signal
A0003.7 1031
Total tools is more than 4, and the external override cannot be
connected
A0004.1 1032
Illegal M code
A0004.2 1033
Spindle jog disabled in non-analog spindle mode
A0004.3 1035 M63,
M64
designation error
A0004.4 1036 Spindle
gear
change time is too long
A0004.5 1037 Spindle
speed/position control switch time is too long
A0004.6
1038
The 2nd spindle speed/position control switch time is too long
A0004.7 1039 Spindle
position control does not permit the orientation
A0005.0
1040
Spindle orientation time is too long
A0005.1
1041
Alarm for the abnormal spindle servo or frequency converter for
abnormality
A0005.2
1042
Alarm for the abnormal 2nd spindle servo or frequency converter
A0005.3
1043
Forbid clamping the spindle when the spindle rotating or feeding
A0005.4
1044
Spindle is clamped not to rotate or feed
A0007.0
2000
Hydraulic motor is not started
A0007.1
2001
Safety door has been opened
A0007.3
2003
Alarm for the tool pot unclocked
A0007.5 2005 Feedrate override is fixed to 100
%
,can't be adjusted
A0007.6 2006
The panel override is disabled when the external override is
enabled.
A0007.7 2007
The program can not be operated due to the external dwell switch is
cut off.
A0008.0
2008
The axis can not be moved due to the manual override is 0.
A0008.3
2011
Machining numbers are reached to the setting one.