Official GSK Agents in South Africa
Tel: +27 11 626 2720, [email protected]
Chapter 3 Parameters
447
Ⅲ
Connection
[
Data range
]
0
~
4080
0
7
3
SPMOTORMAX
[
Data type
]
Word spindle
[
Data meaning
]
Max. spindle motor clamping speed, setting value=(max. spindle motor
clamping speed/max. spindle motor speed) ×4095
[
Data unit
]
r/min
[
Data range
]
0
~
4095
Setting value =
(
max. clamp speed of spindle/max. speed of spindle motor
)
×4095.
0
7
4
SPMOTORMIN
[
Data meaning
]
Min. spindle motor clamping speed, setting value=(min. spindle motor
clamping speed/max. spindle motor speed) ×4095
[
Data unit
]
r/min
[
Data range
]
0
~
4095
Setting value =
(
min. clamping speed of spindle motor/max. speed of spindle motor
)
×4095
0
7
5
SPSPEEDLIMIT
[
Data type
]
Word spindle
[
Data meaning
]
Maximum spindle rev speed(0~6000r/min)[0:unlimited]
[
Data unit
]
r/min
[
Data range
]
0
~
6000
0 7 6
SPDLIMITEXT
[
Data type
]
Word
spindle
[
Data meaning
]
The spindle speed limit when speed limit signal is active [Without restriction when it
is set to 0]
[
Data unit
]
r/min
[
Data range
]
0
~
9999
0 7 7
FEEDLIMITEXT
[
Data meaning
]
The feedrate limit when speed limit signal is active [Without restriction when it is set
to 0].