Official GSK Agents in South Africa
Tel: +27 11 626 2720, [email protected]
GSK980TDi Turning CNC System User Manual
426
Ⅲ
Connection
2.9.26 Handle Interrupt
z
Control parameters
PLC Status parameters
K
1
9
HDFD
HDFD =0: MPG interruption function is disabled in the process of the operation.
=1: MPG interruption function is enabled in the process of the operation.
0 1 2
MPG
interruption
Bit1 1:Handle interrupt is valid
;
0:Handle interrupt is invalid
。
z
Function description
1. When the MPG interruption function is enabled, in the Edit/Auto/MDI mode, enter the MPG
interruption state by the MPG axis number on the selection panel after pressing the
once,
the MPG interruption operation is then can be performed. The MPG interruption can be retracted
by pressing this button again.
2. In the Non-Edit/Auto/MDI mode, the MPG interruption state will be retreated.
3. Whether the MPG interruption is enabled that can be set by K19.5 during the operation of the
program.
4. The panel rapid traverse override can not be adjusted at the state of MPG interruption; the indicator
displays the MPG override state when the MPG override adjustment is enabled.
2.9.27 Chip-Removal Control
z
Relative
signals
Signal
type
Symbol
Signal
interface
Address
Function description
Remark
CHRO+
CN62.43 Y3.6 Chip-removal CW (positive)
Signal
output
CHRO-
CN62.44 Y3.7 Chip-removal CCW (negative)
M38
Chip-removal CW (positive)
Command
format
M39
Chip-removal
stop
z
Relevant parameters
PLCStatus parameters
K
1
3
CHIPR
CHIPR
=1: Chip-removal control enabled.
=0: Chip-removal control disabled.
z
Function
description
1. The reverse rotation of the chip-removal only can be performed the JOG by hand. If the
chip-removal is being rotated, firstly stop the positive rotation when the JOG reverse is performed.
2. When the chip-removal is positively rotated, press the chip-removal positive rotation by hand again,
and then it is closed.
3. Close the chip-removal rotation in the ESP resetting.