Official GSK Agents in South Africa
Tel: +27 11 626 2720, [email protected]
GSK980TDi Turning CNC System User Manual
232
Ⅱ
Operation
The monitor page can view states of current contact, coil ON/OFF state, values of timer and
counter. They are displayed with a green background when they are ON, otherwise, they are the
same those of the page background.
means the contact X0.5 is ON,
means Y25.2 is
OFF.
1. Page program view
In MONITOR page, the system can monitor simultaneously three windows, the ladder blocks
corresponded to each window can be viewed by separately pressing
、
、
,
at the moment, the ladder corresponded to the selected block is displayed on the screen.
2. Window block selection
(
1
)
Select the window which needs to select blocks, press respectively
、
、
to select the windows.
(
2
)
Press
to select the window program. At the moment, the display page is shown below:
(
3
)
Move the cursor to select the ladder block for display.
(
4
)
Press
,
and then return the previous menu, press
to cancel the selection operation
to return to the previous menu.
3. Find parameters, commands and network
(
1
)
Select the required block window for finding commands, parameters and network, make the
corresponding block display in the window, and find the command, parameters and network
in the window.
(
2
)
Respectively press
、
、
to find the corresponding parameter, functional
command and network in the current displayed block, and move the cursor to the
corresponding position.
(
3
)
Press
、
to locate the cursor to the home or end of the current block.