![GSK 980TDi User Manual Download Page 455](http://html1.mh-extra.com/html/gsk/980tdi/980tdi_user-manual_2275219455.webp)
Official GSK Agents in South Africa
Tel: +27 11 626 2720, [email protected]
Chapter 3 Parameters
439
Ⅲ
Connection
2 5 0 *** *** *** ***
*** *** VERI GSKLINK
Bit1 1:System GSKLINK bus communication CRC verification enabled
0:System GSKLINK bus communication CRC verification disabled
Bit0 1: Whether the system GSKLINK bus connection is enabled
0: Whether the system GSKLINK bus connection is disabled
3.1.2 Data Parameter
0 1 5
CMRn
[
Data type
]
Word
axis
[
Data meaning
]
Pulse frequency multiplication coefficient
[
Data range
]
1
~
99999999
0 1 6
CMDn
[
Data type
]
Word
axis
[
Data meaning
]
Pulse frequency division coefficient;
[
Data range
]
1
~
99999999
Explanation: Formula of electric gear ratio:
D
M
Z
Z
L
C
CMD
CMR
*
*
*
4
δ
=
δ
: Least command increment;
Z
M
: Teeth number of pulley on leading screw side;
C:
Motor
encoder
line
number;
Z
D
Teeth number of pulley on motor side;
L: Screw lead
0 1 9
THDCH
[
Data meaning
]
Run-out length in threading
[
Data range
]
0
~
225
Thread run-out width= THDCH×0.1×screw lead
0 2 1
PSANGNT
[
Data type
]
Word
spindle
[
Data meaning
]
Voltage offset value when spindle max. speed analog voltage output is 10V
[
Data unit
]
mV
[
Data range
]
-2000
~
2000(Unit: mV)
0 2 2
RPDFn
[
Data type
]
Word
axis
[
Data meaning
]
Maximum rapid traverse rate of all axes
[
Data unit
]
Setting unit
Data unit
Metric machine
mm/min
Inch machine
0.1inch/min
[
Data range
]
10
~
99999999