Official GSK Agents in South Africa
Tel: +27 11 626 2720, [email protected]
Chapter 3 Parameters
475
Ⅲ
Connection
0:PLC spindle rotation speed function of each axis disabled
。
Bit3 1:Spindle position function is valid (The spindle will perform the mechanical
releasing/clamping interlocking operation before/after positioning when it is enabled);
0:Spindle position function is invalid.
Bit2 1:Servo motor spindle function is valid ,power on
;
0:Servo motor spindle function is invalid ,power on
。
Bit1 1:Change to position mode,the axis do return REF.
0:Change to position mode,the axis don't return REF.
Bit0 1:Cs function of spindle valid ,power on
0:Cs function of spindle is:invalid,power on
1 9 6 ***
***
*** MSEN
*** *** *** ***
Bit4 1: The multiple spindle control is enabled
0: The multiple spindle control is disabled
2 0 1 SNTP *** *** ECN HBR
ERV ***
***
Bit7 1:Synchronization mode follow
0:Synchronization mode interpolation
Bi4 1:Whether the G81 synchronization command can be specified in the synchronization
process allow
0:Whether the G81 synchronization command can be specified in the synchronization
process prohibition
Bit3 1:The system resets in the synchronization process reserve the synchronized control
0:The system resets in the synchronization process cancel the synchronization control
Bit2 1:In the synchronization procedure,in the G99 feed per revolution use the theoretical
revolving speed of workpiece\
0:In the synchronization procedure,in the G99 feed per revolution use the encoder feedback
revolving speed
2 2 0
SP_SERVOn
[
Data type
]
Word
spindle
[
Data meaning
]
The corresponding interface number of each spindle output
[
Data unit
]
[
Data range
]
0
~
14
Setting value
meaning
2
analog spindle interface 2
1
analog spindle interface 1
0
Disabled analog spindle output
11
~
14
extension IO unit analog output
interface; 1~4
2 2 1
SP_SP_CSAXIS
[
Data type
]
Word
spindle
[
Data meaning
]
The functions, such as the feed axis number, CS axis related to each axis must be
set.