![GSK 980TDi User Manual Download Page 460](http://html1.mh-extra.com/html/gsk/980tdi/980tdi_user-manual_2275219460.webp)
Official GSK Agents in South Africa
Tel: +27 11 626 2720, [email protected]
GSK980TDi Turning CNC System User Manual
444
Ⅲ
Connection
[
Data meaning
]
Each retraction for G71, G72 rough turning cycle, which may also be changed
by program code in auto running.
[
Data unit
]
Setting unit
IS-B
IS-C
Metric input
0.001 mm
0.0001 mm
Inch input
0.0001 inch
0.00001 inch
[
Data range
]
0
~
99999
0 5 3
PECSCX
[
Data meaning
]
X retraction amount in G73, which may be also changed by program code in
auto running.
[
Data unit
]
Setting unit
IS-B
IS-C
Metric input
0.001 mm
0.0001 mm
Inch input
0.0001 inch
0.00001 inch
[
Data range
]
-9999999
~
9999999
0 5 4
PECSCZ
[
Data meaning
]
Z axis rough turning retraction in G73, which may also be changed by program
code in auto running
[
Data unit
]
Setting unit
IS-B
IS-C
Metric input
0.001 mm
0.0001 mm
Inch input
0.0001 inch
0.00001 inch
[
Data range
]
-9999999
~
9999999
0 5 5
PATIM
[
Data meaning
]
Cycle times of G73, which may also be changed by program code in auto
running
[
Data unit
]
times
[
Data range
]
1
~
9999
0 5 6
GROVE
[
Data meaning
]
Retraction value of Z axis in G74; retraction value of X axis in G75; a specified
value in program during automatic running can also change the setting of this
parameter;
[
Data unit
]
Setting unit
IS-B
IS-C
Metric input
0.001 mm
0.0001 mm
Inch input
0.0001 inch
0.00001 inch
[
Data range
]
0
~
99999
0 5 7
THRPT
[
Data meaning
]
Repetitions of G76 finish machining, which may also be changed by program