GD32F20x User Manual
401
Mode Selection
Source
Selection
Polarity Selection
Filter and Prescaler
110: CI1FE1
111: ETIFP
configure the ETP for
polarity
selection
and
inversion.
For the ETIF, configure
Filter by ETFC and
Prescaler by ETPSC.
Exam1
Restart mode
The counter can be
clear and restart when
a rising trigger input.
TRGS
[2:0]=3’b
000
ITI0 is the
selection.
-
For ITI0, no polarity
selector can be used.
-
For the ITI0, no filter
and prescaler can be
used.
Figure 18-46. Restart mode
TIMER_CK
CEN
CNT_REG
5E
5F
60
61
62
63
00
01
02
03
04
00
01
02
UPIF
ITI0
TRGIF
Internal sync delay
Exam2
Pause mode
The counter can be
paused
when
the
trigger input is low.
TRGS
[2:0]=3’b
101
CI0FE0 is the
selection.
TI0S=0.
(
Non-xor
)
[CH0NP==0, CH0P==0]
no inverted. Capture will
be sensitive to the rising
edge only.
Filter is bypass in this
example.
Figure 18-47. Pause mode
TIMER_CK
CEN
CNT_REG
5E
5F
60
61
62
CI0
TRGIF
CI0FE0
63