GD32F20x User Manual
390
If the UPDIS bit in TIMERx_CTL0 register is set, the update event is disabled.
When an update event occurs, all the registers (repetition counter, auto reload register,
prescaler register) are updated.
The following figures show some examples of the counter behavior for different clock
prescaler factor when TIMERx_CAR=0x63.
Figure 18-35. Up-counter timechart, PSC=0/1
CEN
CNT_CLK(PSC_CLK)
CNT_REG
5E
5F
60
61
62
63
00
01
02
03
04
05
06
07
Update event (UPE)
Update interrupt flag (UPIF)
CNT_REG
5F
60
Update event (UPE)
Update interrupt flag (UPIF)
Hardware set
Software clear
Hardware set
PSC = 0
PSC = 1
TIMER_CK
08
63
62
61
00
01
02
03
CNT_CLK(PSC_CLK)