7. Messages
7-4
UniSite-xpi User Manual
Cannot copy multiple files into one file.
This message will appear in the Copy Files screen if you attempt to use the wildcard file designation to
copy multiple files to another single file (for example, if you enter “27*.DAT” for the filename, and the files
27128.DAT and 27512.DAT both exist on the disk).
Cannot execute job file while recording job file.
A job file cannot be executed while another is being recorded. You may “chain” job files together by
ending the recording of a job file in the job file execution screen.
Cannot purge file.
This message means that, for some reason other than the disk’s being write-protected, the file cannot be
removed from the disk. If the disk is write-protected, a different message will be generated.
Cannot REPLACE more than 10 Keep Current algorithms.
This message will appear when you try to REPLACE the 11th Keep Current algorithm in a
REPLACE/RESTORE operation.
Cannot update yield tally.
This message will appear after a programming session or during device selection if the System Files disk is
full, write-protected, or contains data errors. The yield tally information is stored on the System Files disk.
Check your disk to see whether it is write-protected. If the disk is NOT write-protected, the cause of the
problem is probably a data error on the System Files disk. User another copy of the System Files disk and
try the same operation; if the problem persists, contact your nearest Data I/O Service Center for assistance.
Cannot use Variable Parameter and Variable Vcc Verify on same device.
This message may appear in two cases:
1) When you try to invoke Variable Parameter on a device algorithm after you have used Variable Vcc
Verify on it.
2) When you try to invoke Variable Vcc Verify on a device algorithm after you have used Variable
Parameter on it.
In either case, to remove the blocking of your desired operation simply select a different device, then select
the device you want and try the operation again.
Checksum error.
The checksum of the data that you downloaded did not match the checksum calculated by the
programmer. Try the operation again. If the problem continues, verify that the checksums generated from
the host are indeed correct.
Compare operation not supported for logic formats.
The compare operation is only available for memory formats.
[Computer Remote Control: enter Control-Z to exit.]
This message informs you that UniSite-xpi is now in remote control mode and all programmer commands
are now read from the remote port. Pressing C
TRL
+ Z returns control to terminal mode.
Constant over-current fault.
This message indicates that an over-current condition exists and UniSite-xpi is unable to clear the
condition. The over current could be caused by a hardware failure in UniSite-xpi. Reboot the system. If the
condition persists, contact Data I/O Customer Support.
Summary of Contents for UniSite-xpi
Page 2: ...981 0014 UniSite Programming System User Manual Also Covering Legacy UniSite Programmers ...
Page 72: ...2 Setup and Installation 2 42 UniSite xpi User Manual ...
Page 134: ...3 Getting Started 3 62 UniSite xpi User Manual ...
Page 238: ...5 Computer Remote Control 5 10 UniSite xpi User Manual ...
Page 296: ...6 Translation Formats 6 58 UniSite xpi User Manual ...
Page 402: ...Keep Current Subscription Service 6 Keep Current ...