7. Messages
UniSite-xpi User Manual
7-19
Install PinSite with PLCC and LCC Base
A device operation was attempted on a device that could be programmed on the PinSite Module with a
PLCC and LCC Base, but the module was not installed.
Install PinSite with SOIC Base
A device operation was attempted on a device that could be programmed on a PinSite Module with an
SOIC Base, but the module was not installed.
Install PGA Base
A device operation was attempted on a device that could be programmed on a PinSite Module with a PGA
Base, but only the PinSite Module is installed. Either no Base or the wrong Base was installed.
Install PLCC and LCC Base
A device operation was attempted on a device that could be programmed on a PinSite Module with a
PLCC and LCC Base, but only the PinSite Module was installed. Either no Base or the wrong Base was
installed.
Install PPI Base
A device operation was attempted on a device that could be programmed on a PinSite Module with a PPI
Base, but only the PinSite Module is installed. Either no Base or the wrong Base was installed.
Install SOIC Base
A device operation was attempted on a device that could be programmed on a PinSite Module with an
SOIC Base, but only the PinSite Module was installed. Either no Base or the wrong Base was installed.
Insufficient pin driver boards for the module/device selected.
The device you are trying to load, program, verify, or check requires more Pin Driver boards than are
installed in your programmer. Each Pin Driver board drives 4 pins. See the User Note for a table of all
Device Pin/Pin Driver Board requirements.
Insufficient pin driver boards for the module/device selected.
The device you are trying to load, program, verify, or check requires more Pin Driver boards than are
installed in your programmer. Each Pin Driver board drives 44 pins.
Intermediate name not directory. (obsolete)
Intermediate name not directory.
Invalid file name.
The filename you entered either contained characters that are not part of the programmer’s character set or
do not conform to the DOS file conventions. Enter a valid filename.
Invalid medium format.
If this message appears when you attempt to mount a disk, reformat your disk and try again.
If this message appears when you attempt to format a disk, your disk might require service. Contact your
nearest Data I/O Service Center.
Invalid operation on directory. (obsolete)
Invalid operation on directory.
Job file already exists.
The filename you selected for the job file is the same as an existing one. Crete a different filename.
Summary of Contents for UniSite-xpi
Page 2: ...981 0014 UniSite Programming System User Manual Also Covering Legacy UniSite Programmers ...
Page 72: ...2 Setup and Installation 2 42 UniSite xpi User Manual ...
Page 134: ...3 Getting Started 3 62 UniSite xpi User Manual ...
Page 238: ...5 Computer Remote Control 5 10 UniSite xpi User Manual ...
Page 296: ...6 Translation Formats 6 58 UniSite xpi User Manual ...
Page 402: ...Keep Current Subscription Service 6 Keep Current ...