7. Messages
7-28
UniSite-xpi User Manual
OPERATION FAILED: Verify Data Error (Both passes).
This message appears when the programmer has performed a verify operation and has found a memory
or fuse cell that was not programmed correctly. The device was verified with its lowest and highest
operating voltages applied and an error was found in both. If this message appears, try another device.
OPERATION FAILED: Verify data error (First pass).
This message appears when the programmer has performed a Verify and has found a memory cell that
was programmed incorrectly. If you selected “2” for the number of Verification passes, the device was
verified with its lowest operating voltage applied. If you selected “1” for the number of Verification
passes, the device was verified with its nominal operating voltage applied. If this message appears, try
another device.
OPERATION FAILED: Verify data error (Second pass).
This message appears when the programmer has performed a Verify and has found a memory cell that
was not programmed correctly. The device was verified with its highest operating voltage applied. If this
message appears, try another device.
Operation not allowed because the device was selected by fam/pincode.
This message appears if you try to perform an operation that the programmer does not allow since the
current device was selected by fam/pincode. Re-select the device by manufacturer and part name and
then try again.
Operation not supported for I/O format selected.
The Upload and Output to Disk operations are not supported for the I/O data format selected. Select a
different format in order to perform the operation desired.
Options installed. Hit Return after changing your terminal settings.
This message appears on the Serial Port Configuration screen after serial port parameters have been
changed and E
NTER
has been pressed. When this message appears, UniSite-xpi suspends screen output
until you press E
NTER
a second time. Make sure you configure the terminal to match the new settings for
the serial port.
Overcurrent
An overcurrent condition was detected during the previous operation. One or more of the socketed
devices may be faulty.
Overrun error during transfer. Data sum = ssssssss.
This error indicates that the data received by the programmer caused an overrun condition on the
programmer’s communication port. Make sure that the programmer’s communication parameters match
those of the machine it is communicating with. If this error occurs after performing a high speed
download, the communication board in your PC may not be able to transfer data at 115.2 Kbd. In this case,
either disable the high speed download feature, or try a different communication board in the PC.
Parameter Entered.
This message acknowledges that the parameter you entered was accepted.
Parameter field full. Hit Return or arrows to enter, ^A to abort.
This message appears when you have tried to enter too many characters into a parameter field. Press the
carriage return, the PF1 or PF2 keys, or use the arrow keys to enter the parameter.
Summary of Contents for UniSite-xpi
Page 2: ...981 0014 UniSite Programming System User Manual Also Covering Legacy UniSite Programmers ...
Page 72: ...2 Setup and Installation 2 42 UniSite xpi User Manual ...
Page 134: ...3 Getting Started 3 62 UniSite xpi User Manual ...
Page 238: ...5 Computer Remote Control 5 10 UniSite xpi User Manual ...
Page 296: ...6 Translation Formats 6 58 UniSite xpi User Manual ...
Page 402: ...Keep Current Subscription Service 6 Keep Current ...