Select Device
Before you can perform any device-related operations with the
programmer, you must select the device you are using.
Before You Select a
Device
Before selecting a device, set the Algorithm Type parameter to the type
of algorithm that matches the device you wish to select.
To set the Algorithm Type, from the Main Menu select More commands/
Configure system/Edit/Programming
(refer to “Algorithm Type” on
page 4-27 for more information).
Note: You can press F1 to return to the Main Menu from any submenu.
The Programming Parameters screen appears. On this screen, set the
Algorithm Type to one of the following:
•
D
(default)—Set the algorithm type to D if you wish to select a
device from the Manufacturer List. The Manufacturer List contains
almost all of the devices supported by your programmer (the
programming algorithms for these devices reside on your Algorithm
disks). Selecting a device from this list is a two-step process: first,
select the device manufacturer and then the device part number.
•
E
(extended algorithm)—Set the algorithm type to E if you wish to
select a device from an Extended Algorithm list. An Extended
Algorithm list contains devices that use extended algorithms for
programming (the programming algorithms for these devices reside
on a disk that contains the extended algorithms). Selecting a device
from this list is a two-step process: first, select the device
manufacturer and then the device part number.
•
K
(Keep Current)—Set the algorithm type to K if you wish to select a
device from a Keep Current list. A Keep Current list contains devices
that use Keep Current algorithms for programming (see “Keep
Current” on page 4-43 for more information).
Note: You can also access Keep Current devices by setting the algorithm type to
D
(default) and selecting
KEEP CURRENT
from the manufacturers list.
•
C
(Custom Menu)—Set the algorithm type to C if you wish to select a
device from a Custom Menu list. A Custom Menu list contains
devices that you included in a Custom Menu (see “Custom Menu
Algs” on page 4-46 for more information).
After setting the Algorithm Type parameter, press F1 to return to the
Main Menu.
Note: See “Save System Parameters” on page 4-38 for instructions on how to
save your Algorithm Type and other parameter changes as power-up
defaults.
Summary of Contents for UniSite-xpi
Page 2: ...981 0014 UniSite Programming System User Manual Also Covering Legacy UniSite Programmers ...
Page 72: ...2 Setup and Installation 2 42 UniSite xpi User Manual ...
Page 134: ...3 Getting Started 3 62 UniSite xpi User Manual ...
Page 238: ...5 Computer Remote Control 5 10 UniSite xpi User Manual ...
Page 296: ...6 Translation Formats 6 58 UniSite xpi User Manual ...
Page 402: ...Keep Current Subscription Service 6 Keep Current ...