3. Getting Started
3-16
UniSite-xpi User Manual
Scroll through the list of device part numbers until the one you want is
highlighted, then click OK.
Session 7: Setting Programmer Properties
After specifying the device to be programmed, the next step is setting the
programmer properties.
From the Setup menu, select General Parameters. These parameters
determine what device operations are performed before, during and after
programming. To learn the parameter’s function, highlight it and then
press F1. The Help topic is displayed.
From the Setup menu, select Memory Parameters to specify how and
where data is loaded in programmer RAM.
To ensure a consistent sumcheck, you can preload all address locations
into RAM with a known hexadecimal value (many data files do not
contain data for every memory address). To do this, select Specific under
Automatic RAM Fill
and enter a value (usually 00 or FF) to be placed in
RAM before a file is loaded.