7. Messages
7-46
UniSite-xpi User Manual
Electronic ID Verify Error on Memory Device
Probable Cause
Solution
Improper device selected
Make sure the device selection matches the manufacturer and part
number of your device as precisely as possible. If it doesn’t select the
proper characteristics and perform the operation again.
Note: Choosing the wrong manufacturer and/or part number (using the Select
device option from the Main Menu) causes the programmer to expect an
electronic ID that differs from the ID in your device.
Device manufacturer has
changed the electronic ID of
the part, and the programmer
does not recognize it
If the device is labeled with a recent date code, the manufacturer may
have placed a new electronic ID on the device that is not recognized by
your programmer. To minimize ID errors, use the latest version of your
programmer software.
Workaround:
If your programmer is at the current version, disable the
Compare elec ID parameter (change from “Y” to “N”) under the Load
Device, Program Device, Verify Device, or Programming Parameters
screen.
Note: You may wish to contact the device manufacturer to find out if they have
changed the ID on the device. If they have, please notify Data I/O
Customer Support.
Faulty device(s)
If disabling the Compare elec ID parameter causes an operation such as
load, program, or verify to fail, try the operation on other devices with
the same date code. If the operation is successful on these devices, the
original device may be defective.
Note: If a high percentage or parts fails the operation, you may wish to contact
the device manufacturer and report your findings.
Possible bug in programmer
software
If disabling the Compare elec ID parameter causes the operation to fail
on a high percentage of parts across several date codes, there may be a
software bug in the programming algorithm associated with the part.
Workaround:
On the programmer’s Device List, find the earliest version
of programmer software that supports the device, boot your
programmer with this version, and repeat the operation. If the operation
is successful, you’ve found a temporary workaround.
Note: Contact Data I/O Customer Support and report your findings.
Summary of Contents for UniSite-xpi
Page 2: ...981 0014 UniSite Programming System User Manual Also Covering Legacy UniSite Programmers ...
Page 72: ...2 Setup and Installation 2 42 UniSite xpi User Manual ...
Page 134: ...3 Getting Started 3 62 UniSite xpi User Manual ...
Page 238: ...5 Computer Remote Control 5 10 UniSite xpi User Manual ...
Page 296: ...6 Translation Formats 6 58 UniSite xpi User Manual ...
Page 402: ...Keep Current Subscription Service 6 Keep Current ...