5. Computer Remote Control
5-2
UniSite-xpi User Manual
System Setup
The programmer receives CRC commands and sends responses to the
host computer through an RS-232C port using a 25-pin D connector in
two possible configurations: either DTE or DCE. Only the Remote port
supports CRC operation.
The pin designations for the Remote port are shown in Appendix B,
“More About Cables.” Included in that appendix is a table of pin
definitions, which explains the function of each pin for the two serial port
configurations.
To ensure correct operation of the Remote port with the host computer,
set the parameters for the Remote port according to the host computer
requirements.
Entering CRC Mode
CRC mode can be entered in either of two ways: by the Remote Control
menu, or automatically at powerup.
By Menu Commands
To enter CRC mode using the Remote Control menu, do the following:
1.
Press F1 to go to the Main Menu.
2.
Type M to select the More Commands menu.
3.
Press R to select Computer Remote Control from the More
Commands menu.
The programmer is now in Remote Control mode.
On Power-up
The programmer enters either terminal or CRC mode during power-up
based on the following combination of port connections and parameter
settings.
Note: X = don’t care condition.
Parameter Settings
Port Connections
Power Up
CRC
User Menu
Port
Terminal
Connected
Remote
Connected Result
Off
T (Terminal)
Yes
Yes
Terminal mode on
Terminal port
Off
T (Terminal)
No
Yes
CRC mode on
Remote port
Off
R (Remote)
X
Yes
Terminal mode on
Remote port
On
X
X
Yes
CRC mode on
Remote port
X
X
Yes
No
Terminal mode on
Terminal port
Summary of Contents for UniSite-xpi
Page 2: ...981 0014 UniSite Programming System User Manual Also Covering Legacy UniSite Programmers ...
Page 72: ...2 Setup and Installation 2 42 UniSite xpi User Manual ...
Page 134: ...3 Getting Started 3 62 UniSite xpi User Manual ...
Page 238: ...5 Computer Remote Control 5 10 UniSite xpi User Manual ...
Page 296: ...6 Translation Formats 6 58 UniSite xpi User Manual ...
Page 402: ...Keep Current Subscription Service 6 Keep Current ...