2.
If you will be using an antistatic wrist strap, put on the wrist strap
and connect it to the programmer. The ground connector for the
antistatic wrist strap is on the side panel of the programmer. Refer to
Figure 1-2 for the location of the ground connector on the
programmer.
WARNING: To help prevent electric shock, the antistatic wrist strap
must contain a 1 M
Ω
(minimum) to 10 M
Ω
(maximum)
isolating resistor.
Connecting the
Power Cord
Connect one end of the ac line cord to the ac receptacle on the rear panel
of the programmer and the other end to a properly grounded ac outlet.
WARNING: To ensure proper grounding, and to avoid hazard of
electrical shock, connect the programmer ONLY to a
properly grounded ac outlet.
The programmer contains a switching power supply that configures itself
to operate on the proper voltage. The power supply accepts voltages
ranging from 90 to 264 Vac and frequencies ranging from 48 to 63 Hz.
Make sure that a module is installed in the programmer. Also, make sure
the device socket in the Base is empty.
CAUTION: Leaving a device in the socket during powerup will cause
power-up self-test failures and could damage the device.
Power up the PC, workstation, or terminal. If you will be controlling the
programmer from a PC or workstation, make sure that the terminal
emulation software (such as HiTerm) is running. If you will be
controlling the programmer from a terminal, make sure that the terminal
is in the proper emulation mode (such as VT-100 mode). See the
“Approved Terminals” section earlier in this chapter for more
information.
Powering Up
Power up the programmer. The power switch is located on the back
panel. When you turn the power switch on, the Power LED should light.
If it doesn’t, turn the programmer off, check the power connections, and
turn the programmer on again.
Note: Do not remove the Boot Files disk while either the Self Test or disk drive
LED is lit. If you remove the Boot Files disk during powerup, you will
need to reboot the programmer.
Did the Programmer Pass
Self-test?
The programmer always performs a self-test upon powerup. The four
front panel LEDs illuminate in different patterns, depending on the
results of the self-test. The programmer has completed powerup when
the Self Test LED and disk drive LED are off. If the Self Test LED does go
off, then go to the section titled “Are the Right LEDs Lit?”
Summary of Contents for UniSite-xpi
Page 2: ...981 0014 UniSite Programming System User Manual Also Covering Legacy UniSite Programmers ...
Page 72: ...2 Setup and Installation 2 42 UniSite xpi User Manual ...
Page 134: ...3 Getting Started 3 62 UniSite xpi User Manual ...
Page 238: ...5 Computer Remote Control 5 10 UniSite xpi User Manual ...
Page 296: ...6 Translation Formats 6 58 UniSite xpi User Manual ...
Page 402: ...Keep Current Subscription Service 6 Keep Current ...