7. Messages
7-20
UniSite-xpi User Manual
Job file operation aborted due to an out of date system parameter file.
This message indicates that a job file recording or playback operation was aborted when the user
attempted to perform a parameter save or restore operation using a system parameter file that is not the
same revision as the current system software. You should perform a save or restore operation while not
recording or using job files, and direct the programmer to update the system parameter file when it
reports that the file is out of date. After updating the parameter file, attempt the job file operation again.
Job file playback ended.
This message informs you that a job file’s playback has ended and you may continue with the operation
where the job file left off.
Job file save aborted. Keystrokes not recorded.
This message appears in the following situation: If you attempt to end job file recording, and either the
system disk is not in the drive or UniSite-xpi has difficulty reading the disk, an error message will appear.
If you press C
TRL
+ Z after seeing that message, the above message will appear.
Key error: Hit space bar to toggle parameter or hit character desired.
This message appears if you tried to type in a parameter using an inappropriate character, such as a letter
instead of a number. Enter a valid parameter.
Keystroke recording ended. Select job file for saving.
This message appears after you have pressed E
SC
, C
TRL
+J a second time to end recording keystrokes for a
job file. Specify a job file number by typing a number between 0 and 9. Then type in a job file description.
Keystroke recording for job file has begun.
After you press E
SC
, C
TRL
+ J once, this message will appear. You are now in the job file record mode:
every keystroke that you make will be recorded. Press E
SC
, C
TRL
+ J a second time to end the session.
Loading data from file.
This message appears while data is being loaded into User RAM from a disk’s data file.
Loading device algorithm.
When you restore a set of system parameters that include a specific device, this message will appear while
the programming algorithm is being loaded.
Loading device algorithm file into user RAM.
This message appears when the device programming algorithm is being loaded into User RAM at the first
device selection operation after the RAM device Selection parameter is enabled.
Loading device menu data.
This message indicates that UniSite-xpi is loading the device and manufacturer selection files.
Loading from disk.
This message appears when UniSite-xpi is reading system information or routines from the disk.
Loading programming parameters.
When you restore a set of system parameters from the Configuration file directory, this message will
appear while the programming parameters are being loaded.
instead of a number. Enter a valid parameter.
Summary of Contents for UniSite-xpi
Page 2: ...981 0014 UniSite Programming System User Manual Also Covering Legacy UniSite Programmers ...
Page 72: ...2 Setup and Installation 2 42 UniSite xpi User Manual ...
Page 134: ...3 Getting Started 3 62 UniSite xpi User Manual ...
Page 238: ...5 Computer Remote Control 5 10 UniSite xpi User Manual ...
Page 296: ...6 Translation Formats 6 58 UniSite xpi User Manual ...
Page 402: ...Keep Current Subscription Service 6 Keep Current ...