ADSP-BF59x Blackfin Processor Hardware Reference
8-39
General-Purpose Timers
Figure 8-18. Timer Status Register
0
0
0
0
0
0
0
31 30
29 28
27 26
25 24
23 22
21 20
19
18 17 16
0
0
0
0
0
0
0
0
0
TIMIL4 (Timer4 Interrupt)
Reset = 0x0000 0000
0
Timer
S
tatus Register (TIMER_
S
TATU
S
)
Read as 1 if timer running, W1C to
abort in PWM_OUT mode
Indicates an interrupt request
when IRQ_ENA is set
TIMIL5 (Timer5 Interrupt)
TRUN6 (Timer6
S
lave
Enable
S
tatus)
TIMIL6 (Timer6 Interrupt)
Indicates that an error or an
overflow occurred
TOVF_ERR4 (Timer4
Counter Overflow)
Read as 1 if timer running, W1C
to abort in PWM_OUT mode
TRUN5 (Timer5
S
lave
Enable
S
tatus)
Read as 1 if timer running, W1C to abort
in PWM_OUT mode
TRUN4 (Timer4
S
lave Enable
S
tatus)
TOVF_ERR5 (Timer5
Counter Overflow)
TOVF_ERR7 (Timer7 Counter Overflow)
Indicates an interrupt request
when IRQ_ENA is set
Indicates an interrupt request
when IRQ_ENA is set
Indicates that an error or an
overflow occurred
Indicates that an error or an overflow occurred
TIMIL7 (Timer7 Interrupt)
Indicates an interrupt request
when IRQ_ENA is set
Read as 1 if timer
running, W1C to abort in
PWM_OUT mode
TRUN7 (Timer7
S
lave Enable
S
tatus)
TOVF_ERR6 (Timer6 Counter Overflow)
Indicates that an error or an overflow occurred
All bits are W1C
0
0
0
0
0
0
15 14
13 12
11 10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
TIMIL0 (Timer0 Interrupt)
0
Read as 1 if timer running, W1C to
abort in PWM_OUT mode
Indicates an interrupt request
when IRQ_ENA is set
TIMIL1 (Timer1 Interrupt)
TRUN2 (Timer2
S
lave Enable
S
tatus)
TIMIL2 (Timer2 Interrupt)
Indicates that an error or an overflow occurred
TOVF_ERR0 (Timer0 Counter Overflow)
Read as 1 if timer running, W1C to abort
in PWM_OUT mode
TRUN1 (Timer1
S
lave Enable
S
tatus)
Read as 1 if timer running, W1C to abort in
PWM_OUT mode
TRUN0 (Timer0
S
lave Enable
S
tatus)
TOVF_ERR1 (Timer1 Counter Overflow)
TOVF_ERR
3
(Timer
3
Counter Overflow)
Indicates an interrupt request
when IRQ_ENA is set
Indicates an interrupt request when
IRQ_ENA is set
Indicates that an error or an overflow occurred
Indicates that an error or an overflow occurred
TIMIL
3
(Timer
3
Interrupt)
Indicates an interrupt request when
IRQ_ENA is set
Read as 1 if timer running, W1C
to abort in PWM_OUT mode
TRUN
3
(Timer
3
S
lave Enable
S
tatus)
TOVF_ERR2 (Timer2 Counter Overflow)
Indicates that an error or an overflow occurred
This diagram shows an example configuration for eight timers. Different products have differ-
ent numbers of timers, therefore some of the bits may not be applicable to your device.
Summary of Contents for ADSP-BF59x Blackfin
Page 64: ...Development Tools 1 22 ADSP BF59x Blackfin Processor Hardware Reference...
Page 74: ...Processor Specific MMRs 2 10 ADSP BF59x Blackfin Processor Hardware Reference...
Page 244: ...Programming Examples 6 40 ADSP BF59x Blackfin Processor Hardware Reference...
Page 700: ...Programming Examples 16 78 ADSP BF59x Blackfin Processor Hardware Reference...
Page 738: ...Boundary Scan Architecture B 8 ADSP BF59x Blackfin Processor Hardware Reference...