2 - 2
2. INSTALLATION
(1) 7kW or less
(a) Installation of one servo amplifier
10mm
or more
10mm
or more
Control box
40mm
or more
Servo amplifier
40mm
or more
Wiring allowance
80mm
or more
Control box
Top
Bottom
(b) Installation of two or more servo amplifiers
POINT
Close mounting is available for the servo amplifier of under 3.5kW for 200V
class and 400W for 100V class.
Leave a large clearance between the top of the servo amplifier and the internal surface of the control
box, and install a cooling fan to prevent the internal temperature of the control box from exceeding the
environmental conditions.
When installing the servo amplifiers closely, leave a clearance of 1mm between the adjacent servo
amplifiers in consideration of mounting tolerances.
In this case, bring the ambient temperature within 0 to 45 (32 to 113 ), or use it at 75% or a smaller
effective load ratio.
Leaving clearance
30mm
or more
30mm
or more
10mm
or more
100mm
or more
Control box
30mm
or more
100mm
or more
Control box
1mm
1mm
40mm or more
Mounting closely
30mm
or more
40mm or more
Top
Bottom
Summary of Contents for Melservo-J3 Series MR-J3-B
Page 19: ...10 MEMO ...
Page 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Page 61: ...2 6 2 INSTALLATION MEMO ...
Page 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Page 241: ...5 62 5 OPERATION MEMO ...
Page 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Page 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Page 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Page 793: ...App 38 APPENDIX MEMO ...
Page 799: ...MEMO ...