7 - 18
7. MR Configurator
7.7.3 Motor-less operation
POINT
When this operation is used in an absolute position detection system, the
home position cannot be restored properly.
Without a servo motor being connected, the output signals are provided and the servo amplifier display shows
the status as if a servo motor is actually running in response to the external I/O signals.
The sequence of the programmable controller (PC) can be checked without connection of a servo motor.
Click "Test" on the menu bar and click "Operation w/o Motor" on the menu.
When the above choices are made, the following window appears.
b)
a)
(1) Execution of motor-less operation ( a) )
Click "Start" to perform motor-less operation.
(2) Termination of motor-less operation ( b) )
Click "Close" to close the window.
Note that just clicking the "Close" button does not cancel motor-less operation. To cancel motor-less
operation, turn ON the power of the servo amplifier and switch to the CC-Link operation mode once.