17 - 59
17. SPEED CONTROL OPERATION
No.
Symbol
Name and function
Initial
value
Unit
Setting
Range
PD25 A8DT CC-Link communication error (A8D) detection time
Select "CC-Link communication error (A8D) detection delay" with parameter
No.PC50 to enable this parameter.
When parameter No.PC50 is set to "0000h", 10ms is set.
Set a value converted from decimal to hexadecimal.
The setting range is up to 1000ms. A value exceeding the setting range will
be limited within the range.
For example) If "03E8h" is set, 1000ms will be set.
The converted decimal value of "1388h" is 10000ms, but it is limited to
1000ms, which is the upper limit of the setting range.
0000h ms 0000h
to
03E8h
CAUTION
If not detecting CC-Link
communication error (A8D),
use the initial setting value
for the communication
time-out detection time.
When you change the
setting value, do not set an
unnecessarily long time
period.
Doing so interferes swift
stop operation at an
occurrence of CC-Link
communication error (A8D).
This parameter is available with servo amplifiers with software version A8 or
later.
When this parameter is set using MR Configurator with software version C5
or earlier, the parameter name is not displayed. However, the setting value is
changeable. Follow the instructions in this Instruction Manual to set the
value.
PD26
Not used in speed control operation.
Do not change the parameter.
0064h
PD27
For manufacturer setting
0000h
PD28
Do not change this value by any means.
0000h
PD29
0000h
PD30
0000h
Summary of Contents for Melservo-J3 Series MR-J3-B
Page 19: ...10 MEMO ...
Page 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Page 61: ...2 6 2 INSTALLATION MEMO ...
Page 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Page 241: ...5 62 5 OPERATION MEMO ...
Page 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Page 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Page 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Page 793: ...App 38 APPENDIX MEMO ...
Page 799: ...MEMO ...