16 - 104
16. INDEXER POSITIONING OPERATION
16.12.4 When alarm or warning has occurred
POINT
As soon as an alarm occurs, make the servo-off status and interrupt the main
circuit power.
Parameter error (A37) and warnings are not recorded in the alarm history.
If any alarm or warning has occurred, refer to (2) or (3) of this section. If a trouble with no alarm or warning has
occurred, refer to 16.12.6 to remove the cause.
(1) Alarms and warning list
When an error occurs during operation, the corresponding alarm or warning is displayed. If any alarm or
warning has occurred, refer to (2), (3) in this section and take the appropriate action. When an alarm occurs,
ALM turns off.
After its cause has been removed, the alarm can be deactivated in any of the methods marked in the
alarm deactivation column.
Display Name
Alarm deactivation
Display
Name
Power
OFF ON
(Note 3)
MR
Configurator
parameter
unit
(Note 2)
Alarm
reset
(RES)
Warnings
A90
Home positioning incomplete
warning
A92
Open battery cable warning
A96
Home
position
setting
error
A97
Next
station
warning
Al
ar
m
s
A10 Undervoltage
A99
Stroke limit warning
A12
Memory error 1 (RAM)
A9D CC-Link warning 1
A13 Clock
error
A9E CC-Link warning 2
A15
Memory error 2
(EEP-ROM)
A9F
Battery
warning
AE0
Excessive
regeneration
warning
A16
Encoder error 1
AE1
Overload
warning
1
(At power on)
AE3 Absolute position counter warning
A17 Board
error
AE6 Servo forced stop warning
A19
Memory error 3 (Flash-ROM)
AE8 Cooling fan speed reduction warning
A1A Motor
combination
error
AE9 Main circuit off warning
A20
Encoder error 2 (during runtime)
AEC
Overload
warning
2
A21
Encoder error 3 (during runtime)
AED Output watt excess warning
A24
Main circuit error
A25
Absolute position erase
A30 Regenerative
error
(Note
1) (Note
1) (Note
1)
A31 Overspeed
A32 Overcurrent
A33 Overvoltage
A37 Parameter
error
A45
Main circuit device overheat
(Note 1) (Note
1) (Note
1)
A46 Servo
motor
overheat
(Note
1) (Note
1) (Note
1)
A47
Cooling fan alarm
A50 Overload
1
(Note
1) (Note
1) (Note
1)
A51 Overload
2
(Note
1) (Note
1) (Note
1)
A52 Error
excessive
A61 Operation
alarm
A8A
Serial communication time-out
error
A8D CC-Link communication error
A8E Serial
communication
error
888 Watchdog
Note 1. Deactivate the alarm about 30 minutes of cooling time after removing the cause of occurrence.
2. Turns on RY(n 1)A or RY(n 3)A.
3. Clicking the "Alarm reset" button on the "Alarm display" screen of MR Configurator allows an alarm to be deactivated.
Pressing the "STOP RESET" key of the parameter unit allows an alarm to be deactivated.
Summary of Contents for Melservo-J3 Series MR-J3-B
Page 19: ...10 MEMO ...
Page 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Page 61: ...2 6 2 INSTALLATION MEMO ...
Page 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Page 241: ...5 62 5 OPERATION MEMO ...
Page 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Page 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Page 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Page 793: ...App 38 APPENDIX MEMO ...
Page 799: ...MEMO ...