14 - 94
14. OPTIONS AND AUXILIARY EQUIPMENT
14.16 EMC filter (recommended)
For compliance with the EN EMC directive, it is recommended to use the following filter. Some EMC filters are
large in leakage current.
(1) Combination with the servo amplifier
Servo amplifier
Recommended filter (Soshin Electric)
Mass [kg]
Model
Rated current
[A]
Rated voltage
[V AC]
Leakage current
[mA]
MR-J3-10T to MR-J3-100T
MR-J3-10T1 to MR-J3-40T1
(Note) HF3010A-UN
10
250
5
3.5
MR-J3-250TN MR-J3-350T (Note)
HF3030A-UN
30
5.5
MR-J3-500T MR-J3-700T (Note)
HF3040A-UN
40
6.5
6
MR-J3-11KT to MR-J3-22KT (Note) HF3100A-UN
100
12
MR-J3-60T4 to MR-J3-100T4
TF3005C-TX
5
500 5.5
6
MR-J3-200T4 to MR-J3-
700T4
TF3020C-TX
20
MR-J3-11KT4 TF3030C-TX
30
7.5
MR-J3-15KT4 TF3040C-TX
40
12.5
MR-J3-22KT4 TF3060C-TX
60
Note. A surge protector is separately required to use any of these EMC filters.
(2) Connection example
1
2
3
4
5
6
E
1
2
3
1
2
3
(Note 1)
Power supply
MCCB
EMC filter
MC
Servo amplifier
L
1
L
2
L
3
L
11
L
21
(Note 2)
Surge protector 1
(RAV-781BYZ-2)
(OKAYA Electric Industries Co., Ltd.)
(Note 2)
Surge protector 2
(RAV-781BXZ-4)
(OKAYA Electric Industries Co., Ltd.)
Note 1. For 1-phase 200V to 230VAC power supply, connect the power supply to L
1
, L
2
and leave L
3
open.
There is no L
3
for 1-phase 100 to 120VAC power supply. Refer to section 1.3 for the power supply specification.
2. The example is when a surge protector is connected.
Summary of Contents for Melservo-J3 Series MR-J3-B
Page 19: ...10 MEMO ...
Page 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Page 61: ...2 6 2 INSTALLATION MEMO ...
Page 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Page 241: ...5 62 5 OPERATION MEMO ...
Page 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Page 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Page 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Page 793: ...App 38 APPENDIX MEMO ...
Page 799: ...MEMO ...