5 - 55
5. OPERATION
5.6.14 Automatic positioning function to the home position
POINT
You cannot perform automatic positioning from outside the position data
setting range to the home position. In this case, make a home position return
again using a manual home position return.
If this function is used when returning to the home position again after performing a manual home position
return after a power-on and deciding the home position, automatic positioning can be carried out to the home
position at high speed. In an absolute position detection system, manual home position return is not required
after power-on.
Please perform a manual home position return beforehand after a power-on.
Set the input signals and parameter as follows.
Item Device/Parameter
used Description
Manual home position return mode
selection
Automatic/manual selection (RYn6)
Turn RYn6 ON.
Point table No. selection 1 to 8
(RYnA to RYnE, RY(n 2)3 to RY(n 2)5)
RYnA to RYnE, RY(n 2)3 to RY(n 2)5 are
turned off.
Home position return speed
Parameter No.PC04
Set the speed till the dog is detected.
Home position return
acceleration/deceleration time
constants
Point table No.1
Use the acceleration/deceleration time constant
of point table No.1.
Set up the home position return speed of the automatic positioning function to the home position by parameter
No.PC04. Use the data of point table No.1 to set the acceleration time constant and deceleration time constant.
When reverse rotation start (RYn2) is ON, it will position automatically at the home position.
ON
OFF
Home position
Servo motor speed
Forward rotation start (RYn1)
Reverse rotation start (RYn2)
Forward
rotation
0r/min
ON
OFF
Home position return speed
parameter No.PC04
Acceleration time constant
of point table No.1
Deceleration time constant
of point table No.1
Summary of Contents for Melservo-J3 Series MR-J3-B
Page 19: ...10 MEMO ...
Page 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Page 61: ...2 6 2 INSTALLATION MEMO ...
Page 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Page 241: ...5 62 5 OPERATION MEMO ...
Page 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Page 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Page 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Page 793: ...App 38 APPENDIX MEMO ...
Page 799: ...MEMO ...