4 - 16
4. SIGNALS AND WIRING
4.3.3 CNP1, CNP2, CNP3 wiring method
POINT
Refer to table 14.1 in section 14.9 for the wire sizes used for wiring.
MR-J3-500T to more, MR-J3-350T4 or more does not have these connectors.
Use the supplied servo amplifier power supply connectors for wiring of CNP1, CNP2 and CNP3.
(1) MR-J3-10T to MR-J3-100T
(a) Servo amplifier power supply connectors
(Note)
Servo amplifier power supply connectors
Connector for CNP1
54928-0670 (Molex)
Applicable cable example
Cable finish OD: to 3.8mm
Connector for CNP2
54928-0520 (Molex)
Connector for CNP3
54928-0370 (Molex)
CNP1
CNP2
CNP3
Servo amplifier
Note. These connectors are of insert type. As the crimping type, the following connectors (Molex) are recommended.
For CNP1: 51241-0600 (connector), 56125-0118 (terminal)
For CNP2: 51240-0500 (connector), 56125-0118 (terminal)
For CNP3: 51241-0300 (connector), 56125-0118 (terminal)
Crimping tool: CNP57349-5300
Applicable cable example
Cable finish OD: to 3.8mm