4 - 19
4. SIGNALS AND WIRING
(b) Termination of the cables
1) CNP1 CNP3
Solid wire: After the insulator has been stripped, the cable can be used as it is.
Insulator
Core
7mm
Twisted wire: Use the cable after stripping the insulator and twisting the core. At this time, take care to
avoid a short caused by the loose wires of the core and the adjacent pole. Do not solder the
core as it may cause a contact fault. Alternatively, a bar terminal may be used to put the wires
together.
Cable size
Bar terminal type
Crimping tool
Manufacturer
[mm
2
]
AWG
For 1 cable
For 2 cables
1.25/1.5 16
AI1.5-8BK
AI-TWIN2 1.5-8BK
2.0/2.5 14
AI2.5-8BU
AI-TWIN2 2.5-10BU CRIMPFOX-ZA3
Phoenix
Contact
3.5 12
AI4-10Y
2) CNP2
CNP2 is the same as MR-J3-100T or smaller capacities. Refer to (1) (b) in this section.