16 - 6
16. INDEXER POSITIONING OPERATION
Signal name
(Device name)
Description
Device No.
Remarks
1 station
occupied
2 stations
occupied
Rotation direction specifying
Turning on/off RYn2 specifies the rotation direction at start.
1. Automatic operation mode 1
Rotation direction changes according to the parameter
No.PA14 setting. RYn2 is used only for the automatic
operation mode 1 (Rotation direction specifying indexer). It is
not used for the automatic operation mode 2 (Shortest
rotating indexer).
RYn2 RYn2
(Note) RYn2
Parameter
No.PA14
Servo motor
rotation direction
0
0 CCW
1
CW
1
0 CW
1
CCW
Note. 0: OFF
1: ON
2. Manual operation mode
It is not affected by the parameter No.PA14.
(Note)
RYn2
Parameter
No.PA14
Servo motor
rotation direction
0
0
CCW
1
1
0
CW
1
Note. 0: OFF
1: ON
3. Home position return mode
RYn2 is invalid. Specify the rotation direction in the home
position return mode by using the parameter No.PC03.
Operation mode selection 1
Select the operation mode.
RYn6
RYn6
Operation mode selection 2
RYn7
RYn7
(Note)
RY of
CC-Link
Operation mode
Ryn7
Ryn6
0
0
Home position return mode
0
1
Manual
operation
mode
1 0
Automatic operation mode 1
(Rotation direction specifying indexer)
1 1
Automatic operation mode 2
(Shortest rotating indexer)
Note.
0:
OFF
1: ON
Summary of Contents for Melservo-J3 Series MR-J3-B
Page 19: ...10 MEMO ...
Page 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Page 61: ...2 6 2 INSTALLATION MEMO ...
Page 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Page 241: ...5 62 5 OPERATION MEMO ...
Page 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Page 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Page 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Page 793: ...App 38 APPENDIX MEMO ...
Page 799: ...MEMO ...