17 - 33
17. SPEED CONTROL OPERATION
(2) Indication list
Display Status
Description
b # #
Waiting for CC-Link
communication
・
The servo amplifier power was switched on when the CC-Link master module power was
off.
・
The CC-Link master module is faulty.
(Note 1)
d # #
Ready
Indicates that initialization is completed, and the servo amplifier is in servo-on state and ready
to operate.
(Note 1)
C # #
Not ready
Indicates that the servo amplifier is being initialized or an alarm has occurred.
(Note 2)
* *
A
Alarm/Warning
Indicates the alarm No./warning No. that occurred. (Refer to section 17.9.4.)
8 8
8
CPU error
Indicates that a CPU watchdog error has occurred.
(Note 3)
0 0.
d
0 0.
C
(Note 3)
Test operation mode
JOG operation, positioning operation, program operation, DO forced output.
(Note 1)
# #.
d
Motor-less operation
# #.
C
Note 1. ## denotes any of numerals 00 to 64 and what it means is listed below.
## Description
00
Set to the test operation mode.
01
Station number 1
02
Station number 2
03
Station number 3
:
:
:
:
62
Station number 62
63
Station number 63
64
Station number 64
2. ** indicates the warning/alarm No.
3. MR Configurator or the MR-PRU03 parameter module is required.
Summary of Contents for Melservo-J3 Series MR-J3-B
Page 19: ...10 MEMO ...
Page 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Page 61: ...2 6 2 INSTALLATION MEMO ...
Page 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Page 241: ...5 62 5 OPERATION MEMO ...
Page 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Page 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Page 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Page 793: ...App 38 APPENDIX MEMO ...
Page 799: ...MEMO ...