16 - 118
16. INDEXER POSITIONING OPERATION
(3) Remedies for warnings
CAUTION
If an absolute position counter warning (AE3) occurred, always make home
position setting again. Not doing so may cause unexpected operation.
POINT
When any of the following warnings has occurred, do not resume operation
by switching power of the servo amplifier OFF/ON repeatedly. The servo
amplifier and servo motor may become faulty. If the power of the servo
amplifier is switched OFF/ON during the warnings, allow more than 30
minutes for cooling before resuming operation.
Excessive regenerative warning (AE0)
Overload warning 1 (AE1)
Always execute a home position return when the forward rotation stroke end
(LSP) or the reverse rotation stroke end (LSN) turns off.
Warnings are not recorded in the alarm history.
When AE6 and AE9 occur, the servo turns off. When any other warning occurs, the operation continues.
However, an alarm may occur, causing improper operation.
Remove the cause of warning according to (3) of this section. Use the MR Configurator to refer to a factor
of warning occurrence.