14 - 54
14. OPTIONS AND AUXILIARY EQUIPMENT
(2) Connection example
MCCB
B C
A
B
C
B
C
R
S
T
N/
P/
24VDC
N
P
C
(Note 7)
Power
supply
Power factor improving reactor
MC
(Note9)
(Note 3, 8) Forced
stop
L
11
L
21
L
1
L
2
L
3
CN6
EMG
DOCOM
CN6
DOCOM
DICOM
ALM
RA
Malfunction
(Note 3, 5)
(Note 2)
P
1
P
2
(Note 4)
RDY
Ready SE
R/L
1
S/L
2
T/L
3
RX
SX
TX
RDY
output
Alarm
output
5m or less
(Note 1)
Phase detection
terminals
Power regeneration
converter FR-RC-(H)
FR-RC-(H)
ALM
RA
OFF
EMG (Note 8)
Operation ready
ON
MC
MC
SK
(Note 6)
Note 1. When not using the phase detection terminals, fit the jumpers across RX-R, SX-S and TX-T. If the jumpers remain removed, the
FR-RC-(H) will not operate.
2. When using servo amplifiers of 5kW and 7kW, always remove the lead of built-in regenerative resistor connected to P terminal
and C terminal.
3. For sink input-output interface. Refer to section 4.8.3 for source input-output interface.
4. P
1
and P
2
are connected by default.
5. The diagram is for when outputting the malfunction (ALM) is enabled by changing the parameter. If disabling malfunction (ALM)
output, configure the power supply circuit which switches off the magnetic contactor after detection of alarm occurrence on the
controller side.
6. Stepdown transformer is required for coil voltage of magnetic contactor more than 200V class in 400V class servo amplifiers.
7. Refer to section 1.2 for the power supply specification.
8. Configure the circuit which shuts off main circuit power with external sequence at forced stop (EMG) off.
9. For the selection of the power factor improving AC reactor, refer to "Power Regeneration Converter FR-RC Instruction Manual
(IB(NA)66330)".
Summary of Contents for Melservo-J3 Series MR-J3-B
Page 19: ...10 MEMO ...
Page 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Page 61: ...2 6 2 INSTALLATION MEMO ...
Page 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Page 241: ...5 62 5 OPERATION MEMO ...
Page 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Page 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Page 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Page 793: ...App 38 APPENDIX MEMO ...
Page 799: ...MEMO ...