6 - 41
6. PARAMETERS
6.4.3 Stopping method when forward rotation stroke end (LSP) or reverse rotation stroke end (LSN) is off
The setting of the first digit of parameter No.PD20 enables to select a stopping method of the servo motor
when the forward rotation stroke end (LSP) or reverse rotation stroke end (LSN) turns off.
Parameter No.PD20
Stopping method for Forward rotation stroke end (LSP) off
or Reverse rotation stroke end (LSN) off
0: Sudden stop (home position erased)
1: Slow stop (home position erased)
2: Slow stop (Deceleration to a stop by deceleration time constant)
3: Sudden stop (Stop by remaining move distance clear)
Setting
value of
parameter
No.PD20
Operation status
Remarks
When rotating at constant speed
When decelerating to stop
0
(Initial
value)
With S-pattern
acceleration/deceleration
Without S-pattern
acceleration/deceleration
LSP
or
LSN
Servo motor
speed
0r/min
ON
OFF
LSP
or
LSN
Servo motor
speed
0r/min
ON
OFF
With S-pattern
acceleration/deceleration
Without S-pattern
acceleration/deceleration
Clears droop pulses
and stops.
Erases the home
position.
A difference occurs
between the command
position and the current
position.
Execute a home
position return again.
1
Amount of
droop pulse
LSP
or
LSN
Servo motor
speed
0r/min
ON
OFF
With S-pattern
acceleration/deceleration
Without S-pattern
acceleration/deceleration
Amount of
droop pulse
With S-pattern
acceleration/deceleration
Without S-pattern
acceleration/deceleration
LSP
or
LSN
Servo motor
speed
0r/min
ON
OFF
Moves for the amount
of droop pulse and
stops.
Erases the home
position.
A difference occurs
between the command
position and the current
position.
Execute a home
position return again.
2
Decelerates to stop
Acceleration/
Deceleration
time constant
Acceleration/
Deceleration
time constant
S-pattern
acceleration/
deceleration
time constant
LSP
or
LSN
Servo motor
speed
0r/min
ON
OFF
With S-pattern
acceleration/deceleration
Without S-pattern
acceleration/deceleration
Continues
decelerating
to stop
LSP
or
LSN
Servo motor
speed
0r/min
ON
OFF
With S-pattern
acceleration/deceleration
Without S-pattern
acceleration/deceleration
Decelerates to stop at
the deceleration time
constant. Continues to
rotate for the amount of
S-pattern
acceleration/decelerati
on time constant delay.
Keeps the home
position.
3
Amount of droop
pulse
LSP
or
LSN
Servo motor
speed
0r/min
ON
OFF
S-pattern
acceleration/
deceleration
time constant
amount of
droop pulse
With S-pattern
acceleration/deceleration
Without S-pattern
acceleration/deceleration
LSP
or
LSN
Servo motor
speed
0r/min
ON
OFF
With S-pattern
acceleration/deceleration
Without S-pattern
acceleration/deceleration
Amount of
droop pulse
S-pattern
acceleration/
deceleration
time constant
amount of
droop pulse
Moves for the amount
of droop pulse and
stops. Continues to
rotate for the amount of
S-pattern
acceleration/decelerati
on time constant delay.
Keeps the home
position.
Summary of Contents for Melservo-J3 Series MR-J3-B
Page 19: ...10 MEMO ...
Page 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Page 61: ...2 6 2 INSTALLATION MEMO ...
Page 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Page 241: ...5 62 5 OPERATION MEMO ...
Page 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Page 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Page 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Page 793: ...App 38 APPENDIX MEMO ...
Page 799: ...MEMO ...