14 - 66
14. OPTIONS AND AUXILIARY EQUIPMENT
Servo motor
rotation
Forward
rotation
Malfunction (ALM)
Base
Dynamic brake
Interlock (DB)
Dynamic brake
Forced stop
(EMG)
ON
OFF
ON
OFF
ON
OFF
Invalid
Valid
Short
Open
a. Timing chart at alarm occurrence
b. Timing chart at Forced stop (EMG) validity
Dynamic brake
Coasting
Coasting
Dynamic brake
0r/min
Servo motor speed
Base circuit
Electromagnetic
brake interlock (MBR)
Malfunction (ALM)
Main circuit
Control circuit
Power
Dynamic brake
Interlock (DB)
Dynamic brake
Valid (OFF)
Invalid (ON)
OFF
ON
OFF
ON
OFF
ON
Valid (OFF)
Invalid (ON)
OFF
ON
0r/min
Forward
rotation
Coasting
Dynamic brake
Electromagnetic
brake interlock
(Note 1) 7ms
10ms
(Note 2) 15 to 60ms
Electromagnetic
brake operation
delay time
Note 1. When powering off, dynamic brake interlock (DB) will be turned off, and the base circuit will be turned off earlier
than usual before an output shortage occurs.
(Only when assigning the DB as the output signal)
2. Variable according to the operation status.
c. Timing chart when both of the main and control circuit power are OFF.
Summary of Contents for Melservo-J3 Series MR-J3-B
Page 19: ...10 MEMO ...
Page 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Page 61: ...2 6 2 INSTALLATION MEMO ...
Page 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Page 241: ...5 62 5 OPERATION MEMO ...
Page 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Page 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Page 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Page 793: ...App 38 APPENDIX MEMO ...
Page 799: ...MEMO ...