16 - 26
16. INDEXER POSITIONING OPERATION
(2) Movement completion rough match in position
POINT
If an alarm cause, etc. are removed and servo-on occurs after a stop is made
by servo-off, alarm occurrence or Forced stop (EMG) ON during automatic
operation, Movement completion (MEND), Rough-match, (CPO) and In
position (INP) are turned on. To resume operation, confirm the current
position and the selected point table No. for preventing unexpected operation.
(a) Movement completion
The following timing charts show the output timing relationships between the position command
generated in the servo amplifier and the movement completion (RYnC). This timing can be changed
using parameter No.PA10 (in-position range). RYnC turns ON in the servo-on status.
Position command and
servo motor speed
3ms or less
In-position range
Servo motor speed
Position command
ON
ON
Start (RYn1)
Movement completion (RXnC)
OFF
OFF
When parameter No.PA10 is small
Position command and
servo motor speed
3ms or less
In-position range
Servo motor speed
Position command
ON
ON
Start (RYn1)
Movement completion (RXnC)
OFF
OFF
When parameter No.PA10 is large
Summary of Contents for Melservo-J3 Series MR-J3-B
Page 19: ...10 MEMO ...
Page 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Page 61: ...2 6 2 INSTALLATION MEMO ...
Page 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Page 241: ...5 62 5 OPERATION MEMO ...
Page 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Page 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Page 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Page 793: ...App 38 APPENDIX MEMO ...
Page 799: ...MEMO ...