17 - 34
17. SPEED CONTROL OPERATION
17.7 Speed control operation
17.7.1 Changing speed by devices of speed selection 1 (RYnA) to speed selection 3 (RYnC) (common when
1 station/2 stations are occupied)
Forward rotation start (RYn1)
Reverse rotation start (RYn2)
Speed selection 1 (RYnA)
Speed selection 2 (RYnB)
Speed selection 3 (RYnC)
Speed acceleration/
deceleration selection (RYnD)
Servo motor
Speed
Forward rotation
0 r/min
Reverse rotation
Speed reached (RXn5)
Zero speed detection (RXnF)
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Acceleration/deceleration time
constants of point table No.1
Point table No.1
Servo motor speed
Point table No.2
Servo motor speed
Acceleration/deceleration time
constants of point table No.2
Point table No.3
Servo motor speed
Point table No.5
Servo motor speed
17.7.2 Changing speed by remote register (only when 2 stations are occupied)
(1) When parameter No.PC50=
0
Forward rotation start (RYn1)
Reverse rotation start (RYn2)
Speed command data (RWwn+6)
Speed specifying system
selection (RY(n+2)A)
Speed command execution
demand (RY(n+2)1)
Speed command execution
completion (RX(n+2)1)
Speed acceleration/deceleration
selection (RYnD)
Servo motor
Speed
Forward rotation
Reverse rotation
0 r/min
Speed reached (RXn5)
Speed reached (RXn5)
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Acceleration/deceleration time
constants of point table No.1
Acceleration/deceleration time
constants of point table No.2
Summary of Contents for Melservo-J3 Series MR-J3-B
Page 19: ...10 MEMO ...
Page 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Page 61: ...2 6 2 INSTALLATION MEMO ...
Page 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Page 241: ...5 62 5 OPERATION MEMO ...
Page 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Page 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Page 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Page 793: ...App 38 APPENDIX MEMO ...
Page 799: ...MEMO ...