1 - 9
1. FUNCTIONS AND CONFIGURATION
Servo amplifier
MR-J3-
Item
10T 20T 40T 60T 70T 100T 200TN 350T 500T 700T 11KT 15KT 22KT 10T1 20T1 40T1
E
nv
ironm
ent
Ambient
temperature
In operation
[ ] 0
to
55 (non-freezing)
[ ] 32
to
131 (non-freezing)
In storage
[ ]
20 to 65 (non-freezing)
[ ]
4 to 149 (non-freezing)
Ambient
humidity
In operation
90%RH or less (non-condensing)
In storage
Ambient
Indoors (no direct sunlight)
Free from corrosive gas, flammable gas, oil mist, dust and dirt
Altitude
Max. 1000m above sea level
Vibration resistance
5.9m/s
2
, 10 to 55Hz (directions of X, Y and Z axes)
Mass
[kg] 0.8 0.8 1.0 1.0 1.4 1.4 2.1 2.3 4.6 6.2 18 18 19 0.8 0.8 1.0
[lb] 1.76 1.76 2.21 2.21 3.09 3.09 4.63 5.07 10.1 13.7 39.7 39.7 41.9 1.76 1.76 2.21
Note 1. 0.15A is the value applicable when all I/O signals are used. The current capacity can be decreased by reducing the number of
I/O points.
2. Operate them at the ambient temperatures of 0 to 45 (32 to 113 ) or at 75% or smaller effective load ratio.
3. Use an external dynamic brake for this servo amplifier. Failure to do so will cause an accident because the servo motor does not
stop immediately but coasts at emergency stop. Ensure the safety in the entire equipment.
4. When a UL/cUL- compliant servo motor is used in combination, the value is 2.9A.
Summary of Contents for Melservo-J3 Series MR-J3-B
Page 19: ...10 MEMO ...
Page 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Page 61: ...2 6 2 INSTALLATION MEMO ...
Page 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Page 241: ...5 62 5 OPERATION MEMO ...
Page 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Page 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Page 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Page 793: ...App 38 APPENDIX MEMO ...
Page 799: ...MEMO ...