16 - 23
16. INDEXER POSITIONING OPERATION
16.3 Signal
16.3.1 Signal (device) explanation
POINT
In the indexer positioning operation, devices assigned to the CN6 connector
cannot be changed.
(1) I/O device
(a) Input device
POINT
Devices assigned to CN6 connector and RY of CC-Link cannot be used
simultaneously.
Device Symbol
Connector
pin No.
Functions/Applications
Forced stop
EMG
CN6-1
When EMG is turned off, the operation will be stopped forcibly. At this time, the
servo turns off, and the dynamic brake operates to stop the servo motor
suddenly.
The forced stop will be reset when EMG is turned on.
Proximity dog
DOG
CN6-2
When DOG is turned OFF, the proximity dog is detected. The polarity of dog
detection can be changed using parameter No.PD16.
Parameter
No.PD16
Proximity dog (DOG)
detection polarity
0
(initial value)
OFF
1
ON
Forward rotation stroke end
LSP
CN6-3
When starting operation, turn LSP/LSN to ON. Turning it to OFF causes a
sudden stop, resulting in servo lock. A stopping method can be changed in
parameter No.PD20.
When not using the forward/reverse rotation stroke end, set "Automatic ON" in
parameter No.PD01.
Reverse rotation stroke end
LSN
CN6-4
(Note)
Input
signal
Operation
LSP
LSN
CCW
direction
CW
direction
1
1
0
1
1
0
0
0
Note. 0: OFF
1: ON
Summary of Contents for Melservo-J3 Series MR-J3-B
Page 19: ...10 MEMO ...
Page 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Page 61: ...2 6 2 INSTALLATION MEMO ...
Page 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Page 241: ...5 62 5 OPERATION MEMO ...
Page 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Page 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Page 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Page 793: ...App 38 APPENDIX MEMO ...
Page 799: ...MEMO ...