2) Rotation direction selection (parameter No.PA14)
Choose the servo motor rotation direction at the time when the forward rotation start (RYn1) is
switched on.
Parameter No.PA14 setting
Servo motor rotation direction
when forward rotation start (RYn1) is switched on
0
CCW rotation with position data
CW rotation with position data
1
CW rotation with position data
CCW rotation with position data
CW
CCW
3) Feed length multiplication selection (parameter No.PA05)
Set the unit multiplication factor (STM) of position data.
Parameter No.PA05 setting
Feed unit [
μ
m]
Position data input range [mm]
0
1
999.999 to 999.999
1
10
9999.99 to 9999.99
2
100
99999.9 to 99999.9
3
1000
999999 to 999999
(c) Operation
Choosing the point table using RYnA to RYnE, RY(n 2)3 to RY(n 2)5 and turning RYn1 ON starts
positioning to the position data at the preset speed, acceleration time constant and deceleration time
constant. At this time, reverse rotation start (RYn2) is invalid.
Item Setting
method
Description
Automatic operation mode selection
Automatic/manual selection (RYn6)
Turn RYn6 ON.
Point table selection
Point table No. selection 1 (RYnA)
Point table No. selection 2 (RYnB)
Point table No. selection 3 (RYnC)
Point table No. selection 4 (RYnD)
Point table No. selection 5 (RYnE)
Point table No. selection 6 (RY(n 2)3)
Point table No. selection 7 (RY(n 2)4)
Point table No. selection 8 (RY(n 2)5)
Refer to section 5.4.1(2).
Start
Forward rotation start (RYn1)
Turn RYn1 ON to start.
Summary of Contents for Melservo-J3 Series MR-J3-B
Page 19: ...10 MEMO ...
Page 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Page 61: ...2 6 2 INSTALLATION MEMO ...
Page 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Page 241: ...5 62 5 OPERATION MEMO ...
Page 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Page 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Page 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Page 793: ...App 38 APPENDIX MEMO ...
Page 799: ...MEMO ...