17 - 61
17. SPEED CONTROL OPERATION
17.9.2 State at error occurrence
If an error occurs during operation, it will be the state shown below.
Error location
Description
Operation mode
Test operation
CC-Link operation
Servo side
alarm occurrence
Servo operation
Stop
Stop
CC-Link data communication
Continue
Continue
CC-Link
communication error
Servo operation
Stop
Stop
CC-Link data communication
Stop
Stop
Programmable
controller error
STOP
Servo operation
Continue
Stop
CC-Link data communication
Stop
Stop
Servo side
warning occurrence
Servo operation
Stop
Continue
CC-Link data communication
Continue
Continue
17.9.3 CC-Link communication error
The table below shows the detailed description of the communication alarm display area. The servo amplifier
has four LED indications.
L.RUN: Lit at normal reception of refresh data. Turned off when data is not received for a given period of time.
SD : Lit when send data is "0".
RD : Lit when the carrier of reception data is detected.
L.ERR: Lit when the data addressed to the host is in CRC or abort error.
(Note) Communication alarm display LED
Fault
L.RUN SD RD L.ERR
Normal communication is made, but a CRC error sometimes occurs due to noise.
Normal communication
Hardware fault
Hardware fault
Receive data results in CRC error, disabling a response.
Data does not reach the host.
Hardware fault
Hardware fault
Hardware fault
Polling response is made, but refresh receive is in CRC error.
Hardware fault, or manufacturer setting switch (SW2) changed
Hardware fault
Hardware fault
Data addressed to the host resulted in CRC error.
Data does not reach the host, or the data addressed to the host cannot be
received due to noise.
Hardware fault
Baud rate setting illegal
Station number setting illegal
Baud rate or station number setting changed midway (ERROR flickers for about
0.4s.)
Data cannot be received due to power-off, power supply failure, open cable, etc.
WDT error occurrence (hardware error)
Note.
:Lit :Extinguished :Flicker
Summary of Contents for Melservo-J3 Series MR-J3-B
Page 19: ...10 MEMO ...
Page 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Page 61: ...2 6 2 INSTALLATION MEMO ...
Page 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Page 241: ...5 62 5 OPERATION MEMO ...
Page 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Page 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Page 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Page 793: ...App 38 APPENDIX MEMO ...
Page 799: ...MEMO ...